SmartDFE v4.2 Release Notes



Important Upgrade Notes

If you have updated your template config files in a previous version, please note that config files are now stored in ProgramData. We recommend that you back up your config files before installing this version of SPC and migrate your changes across to the config files found in ProgramData after installation. For example, C:\Program Files\Global Graphics\Smart Print Controller\ConfigFiles will have your current config files, but SPC v4.2 now looks for them in  C:\ProgramData\Smart Print Controller\ConfigFiles and will install its config files there.

When saving settings, they are stored in a .spc file and this now includes all config files inside it. When settings are loaded from a .spc file, config files in C:\ProgramData\Smart Print Controller\ConfigFiles are overwritten with those from the .spc file. For backwards compatibility, previous .pcc files (which do not include config files) can still be used to load settings if they are renamed to .spc. Loading from these files will not change any config files in ProgramData. If you save out to .spc after loading, then all your config files will now be saved as well.

New Features and Bug Fixes

Jira Story

Description


Integrated Harlequin Direct 1.11.1.1 with Harlequin Core 13.2r4


Integrated new Streamline Direct Estimate that determines suitable iHVD settings


Settings are now saved in SPC files (.spc) and include all config files


Config files used by Harlequin Direct are now stored in ProgramData rather than Program Files


The Waiting Queue can now be maximized to see more job details


Maximized Waiting Queue shows job dimensions and total pages


Jobs can now have Target Media specified and Media mismatches are handled


SMD files are now included in Support Packages


Harlequin Direct is now referred to as RIP Server in the UI and the log


Addressed a banding issue by enforcing PDF/X color management and more smoothness


The size of each area in the Queues pane is now remembered between launches


Horizontal and Vertical Scaling can now be specified with up to three decimal places


Standardized all server and Harlequin Direct references to RIP Server


Display of log shown in the Support Pane is truncated to 6000 entries


Jobs can be duplicated with page selection over OPC


Sending to print queue over OPC now returns RequestDenied when the move was not possible


Jobs can now have labels added to them for grouping and filtering over OPC


Information from SmartPCRemote can now be accessed over OPC


Improvements to OPC documentation generation


The OPC endpoint shown in the UI now includes the PC name


CalibrationJustification and CalibrationOffset can now be set over OPC


Fixed an OPC issue where ActiveJob.GUID was updated before some other properties


Fixed a bug where pane navigation was disabled after closing the Job Editor with External Control enabled


Fixed a bug where the application could crash occasionally after Reverting settings


Fixed a bug where the Media Length was incorrect when using refresh pages at the start of a print run and multiple copies


Fixed a bug where printing remotely from an OPC Client was failing


Fixed a bug where the Active Media in Setup->Media could show incorrect values


Fixed a bug where the Completed Queue could not be restored after using the Job Information Page