This page applies to Harlequin v13.1r0 and later; and to Harlequin MultiRIP but not Harlequin Core
D_GEN_SHUTDOWN Selector
Parameter: GenericShutdownParam * param
Call type: Single call
This call occurs only when the RIP is shut down, and is provided for the plugin to take whatever action is necessary to terminate itself.
typedef struct genericShutdownParam { int32 version ;
} GenericShutdownParam ;
version
The version field should be ignored.